{"id":150,"date":"2014-12-17T15:56:42","date_gmt":"2014-12-17T15:56:42","guid":{"rendered":"http:\/\/lucanegri.biz\/cavallosrl\/?p=150"},"modified":"2019-09-12T11:40:08","modified_gmt":"2019-09-12T11:40:08","slug":"stability-test-chamber-ctao","status":"publish","type":"post","link":"https:\/\/www.cavallocom.it\/en\/stability-test-chamber-ctao\/","title":{"rendered":"Stability Test Chamber CTA"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p>Technical characteristics:<\/p>\n<ul>\n<li>Temperature and Humidity control.<\/li>\n<li>Standard ICH Q1A(R2) Stability Tests:<\/li>\n<li>Long term Test:\u00a0 +25<span class=\"upd\">\u00b0<\/span>C\u00b12<span class=\"upd\">\u00b0<\/span>C\/60%HR\u00b15%,<\/li>\n<li>Short term Test: +30<span class=\"upd\">\u00b0<\/span>C\u00b12<span class=\"upd\">\u00b0<\/span>C\/65%HR\u00b15%,<\/li>\n<li>Short term Test: +40<span class=\"upd\">\u00b0<\/span>C\u00b12<span class=\"upd\">\u00b0<\/span>C\/75%HR\u00b15%,<\/li>\n<li>Short term Test: +30<span class=\"upd\">\u00b0<\/span>C\u00b12<span class=\"upd\">\u00b0<\/span>C\/75%HR\u00b15% (Zone 3 and 4).<\/li>\n<li>Outer case in stainless epoxy painted steel plate with acid and rust-proof ground.<\/li>\n<li>Internal chamber in stainless steel 18\/8 as per AISI 304.<\/li>\n<li>External front door in enamelled steel and interior in stainless steel with silicone rubber gasket.<\/li>\n<li>Inner transparent glass Door with aluminium frame.<\/li>\n<li>Thermo insulation through thick rock wool panels.<\/li>\n<li>Heating provided by n.2 stainless steel sheathed resistors easy to replace.<\/li>\n<li>CFC free refrigerating device.<\/li>\n<li>Overpowered compressor.<\/li>\n<li>Humidity device through hot steam generator (to be filled with treated water only).Tank with floating level included.<\/li>\n<li>Fan forced air circulation.<\/li>\n<\/ul>\n<p>Control Panel Board completed with:<\/p>\n<ul>\n<li>Temperature Digital Microprocessor Thermo-Regulator Ascon M33107, auto-tuning P.I.D. control 4-20 mA signal re-transmission for Recorder connection.<\/li>\n<li>Humidity Digital Microprocessor Thermo-Regulator Ascon M33107, auto-tuning P.I.D. control 4-20 mA signal re-transmission for Recorder connection.<\/li>\n<li>Min\/max safety thermostats with visible alarms.<\/li>\n<li>Mains Switch.<\/li>\n<li>Refrigerating Device Switch -Humidity Device Switch.<\/li>\n<li>Humidity Safety Lamp (Lack of Water in Tank) -Safety Lamps.<\/li>\n<li>Fuses.<\/li>\n<\/ul>\n<p>V. 230\/1 Hz. 50 CEI 62-25 Electric device \u2013 CE Marking<\/p>\n<table style=\"height: 205px;\" width=\"635\">\n<tbody>\n<tr>\n<td style=\"text-align: left;\" width=\"152\">Model<\/td>\n<td width=\"88\">Int.dim.lxpxh cm<\/td>\n<td width=\"51\">Volume<\/td>\n<td width=\"74\">shelves (max)<\/td>\n<td width=\"116\">Ext.dim.lxpxh cm<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">C3TAU bench\/floor<\/td>\n<td width=\"88\">61x63x60<\/td>\n<td width=\"51\">230<\/td>\n<td width=\"74\">2 (6)<\/td>\n<td width=\"116\">102x80x113\/130<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">C4TAU floor<\/td>\n<td width=\"88\">61x63x100<\/td>\n<td width=\"51\">384<\/td>\n<td width=\"74\">3 (8)<\/td>\n<td width=\"116\">102x80x160<\/td>\n<\/tr>\n<tr>\n<td width=\"152\">C5TAU pavimento<\/td>\n<td width=\"88\">61x63x140<\/td>\n<td width=\"51\">538<\/td>\n<td width=\"74\">4 (12)<\/td>\n<td width=\"116\">102x80x200<\/td>\n<\/tr>\n<tr>\n<td width=\"152\"><\/td>\n<td width=\"88\"><\/td>\n<td width=\"51\"><\/td>\n<td width=\"74\"><\/td>\n<td width=\"116\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Options:<\/p>\n<ul>\n<li>Walk-in models.<\/li>\n<li>Lighting Device for Photostability Test.<\/li>\n<li>Temperature\/Humidity Programmers.<\/li>\n<li>Temperature\/Humidity Protocols.<\/li>\n<li>IQ\/OQ Protocols and Protocol Tests.<\/li>\n<li>Video Recorder with colour Display \u2018Memograph M RSG40\u2019 with n. 4\/8\/12 channels.<\/li>\n<li>FDA 21CFR Part 11 user administration.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<span class=\"woo-sc-ilink\"><a class=\"info\" href=\"http:\/\/www.cavallocom.it\/wp-content\/uploads\/2015\/03\/CTAU-STABILITY-TEST-CHAMBER.pdf\">Download PDF<\/a><\/span>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Technical characteristics: Temperature and Humidity control. Standard ICH Q1A(R2) Stability Tests: Long term Test:\u00a0 +25\u00b0C\u00b12\u00b0C\/60%HR\u00b15%, Short term Test: +30\u00b0C\u00b12\u00b0C\/65%HR\u00b15%, <a class=\"read-more\" href=\"https:\/\/www.cavallocom.it\/en\/stability-test-chamber-ctao\/\">&#8230; [read more]<\/a><\/p>\n","protected":false},"author":1,"featured_media":147,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[34],"tags":[],"class_list":["post-150","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-stability-test-chamber"],"_links":{"self":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/comments?post=150"}],"version-history":[{"count":6,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/150\/revisions"}],"predecessor-version":[{"id":809,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/150\/revisions\/809"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/media\/147"}],"wp:attachment":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/media?parent=150"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/categories?post=150"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/tags?post=150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}