{"id":141,"date":"2014-12-17T15:32:23","date_gmt":"2014-12-17T15:32:23","guid":{"rendered":"http:\/\/lucanegri.biz\/cavallosrl\/?p=141"},"modified":"2015-03-11T10:41:33","modified_gmt":"2015-03-11T10:41:33","slug":"stability-test-chamber-1700cfu","status":"publish","type":"post","link":"https:\/\/www.cavallocom.it\/en\/stability-test-chamber-1700cfu\/","title":{"rendered":"Stability Test Chamber 1700CFU"},"content":{"rendered":"<p><a href=\"http:\/\/lucanegri.biz\/cavallosrl\/wp-content\/uploads\/2014\/12\/CPS-1700CFU.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-138\" src=\"http:\/\/lucanegri.biz\/cavallosrl\/wp-content\/uploads\/2014\/12\/CPS-1700CFU-300x258.png\" alt=\"CPS-1700CFU\" width=\"300\" height=\"258\" srcset=\"https:\/\/www.cavallocom.it\/wp-content\/uploads\/2014\/12\/CPS-1700CFU-300x258.png 300w, https:\/\/www.cavallocom.it\/wp-content\/uploads\/2014\/12\/CPS-1700CFU-1024x882.png 1024w, https:\/\/www.cavallocom.it\/wp-content\/uploads\/2014\/12\/CPS-1700CFU.png 1199w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><strong>STABILITY TEST CHAMBER mod. 1700CFU<\/strong><\/p>\n<p><strong>Temperature range: +15<span class=\"upd\">\u00b0<\/span>C\/+50<span class=\"upd\">\u00b0<\/span>C<\/strong> (accuracy \u00b11<span class=\"upd\">\u00b0<\/span>C all over inside the chamber) (read on display \u00b1 0,1) .<\/p>\n<p><strong>Humidity <\/strong>range: <strong>from ambient to 85% <\/strong>\u00a0(accuracy \u00b13 all over inside the chamber) (read on display \u00b10,1) .<\/p>\n<p><strong>Stability Test to be chosen among: <\/strong>25<span class=\"upd\">\u00b0<\/span>C with 60% Humidity; 30<span class=\"upd\">\u00b0<\/span>C with 65% Humidity;\u00a0 30<span class=\"upd\">\u00b0<\/span>C with 75% Humidity; 40<span class=\"upd\">\u00b0<\/span>C with 75% Humidity.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Real performance scheme of our Stability Chamber:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"118\">\n<p style=\"text-align: center;\"><strong>Temperature T<span class=\"upd\">\u00b0<\/span>C<\/strong><\/p>\n<\/td>\n<td width=\"85\"><strong>min R.H. %<\/strong><\/td>\n<td width=\"95\"><strong>max R.H. %<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"118\">15<\/td>\n<td width=\"85\">55,7<\/td>\n<td width=\"95\">92<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">20<\/td>\n<td width=\"85\">50,5<\/td>\n<td width=\"95\">95,5<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">25<\/td>\n<td width=\"85\">42,5<\/td>\n<td width=\"95\">99,9<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">30<\/td>\n<td width=\"85\">38,6<\/td>\n<td width=\"95\">97<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">35<\/td>\n<td width=\"85\">31,7<\/td>\n<td width=\"95\">95<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">40<\/td>\n<td width=\"85\">27,0<\/td>\n<td width=\"95\">95<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">50<\/td>\n<td width=\"85\">25<\/td>\n<td width=\"95\">94<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">55<\/td>\n<td width=\"85\">23<\/td>\n<td width=\"95\">94<\/td>\n<\/tr>\n<tr>\n<td width=\"118\">60<\/td>\n<td width=\"85\">19,6<\/td>\n<td width=\"95\">81<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>\u2205<\/strong> 35 mm. Validation Port<\/p>\n<p><strong>Construction<\/strong>: stainless steel as per AISI 304 (inside and outside)<\/p>\n<p><strong>Cast-iron Sheets <\/strong>Stainless steel 304 18\/8-18\/10: thickness 0.6 mm for perimeter panels and floor<\/p>\n<p><strong>Insulation:<\/strong> high density polyurethane mm.60<\/p>\n<p><strong>double front Door<\/strong>: stainless steel front door<\/p>\n<p>PVC profile with a rounded corner for condensate-free connection to the internal plate,<br \/>\nPVC gasket with double tube.<\/p>\n<p><strong>Conditioning device <\/strong>through C.F.C. free air refrigerating device<\/p>\n<p>Inner ventilation through n.3 fans to optimise temperature<\/p>\n<p>Plenum for optimal circulation and uniformity<\/p>\n<p><strong>Evaporator <\/strong>will be positioned inside the chamber<\/p>\n<p><strong>Refrigerating device Technical description:<\/strong><\/p>\n<p>Refrigerating Group suitably protected, to be positioned on top of the chamber.<\/p>\n<ul>\n<li>Refrigerating group type hermetic SCROLL with <strong>AIR<\/strong> condeser, gas R134A.<\/li>\n<li>Deidrating filter, electro-valve for liquid, expansion\u00a0hermostatic valve, high\/low pressure pressostat,<\/li>\n<li>Mounted in independent powder RAL 9002 painted steel fairing.<\/li>\n<li>Copper\/Aluminium Aeroevaporator, complete with resistors<\/li>\n<li>Copper piping to connect Refrigerating group and evaporator<\/li>\n<\/ul>\n<p><strong>Heating <\/strong>through resistors<\/p>\n<p><strong>Service Lamp<\/strong> through switch and light positioned outside the door.<\/p>\n<p><strong>Humidity device<\/strong> through hot steam generator + 30lt tank to be filled with treated water<\/p>\n<p><strong>Stainless steel SHELVING<\/strong> (ecoinox) composed by:<\/p>\n<ul>\n<li>Base Element cm.150x70x140H with n.5 perforated Shelves in polyethylene.<\/li>\n<li>Each shelf cm.150&#215;70 can be loaded with n.12 plastic boxes mm.300x220x105= tot. n.60.<\/li>\n<\/ul>\n<p><strong>Control panel<\/strong> complete with:<\/p>\n<ul>\n<li><strong>Ascon M3 3107<\/strong> Temperature microprocessor regulator P.I.D. autotuning with automatic calibration\u00a0of set parameters<\/li>\n<li><strong>Ascon M3 3107<\/strong> Humidity microprocessor regulator P.I.D. autotuning with automatic calibration\u00a0of set parameters<\/li>\n<li>Min max safety regulators with sound\/visual alarm<\/li>\n<li>Under and over-temperature safety alarm for deviation from set point \u00b12<\/li>\n<li>Under and over humidity % safety alarm for deviation from set point \u00b15<\/li>\n<li>Lack of water safety<\/li>\n<li>Compressor failure alarm through low pressure pressostat<\/li>\n<li>Alarm system for Temperature and Humidity\u00a0 through \u2018clean contact\u2019 NO (normally Open)\u00a0and NC (normally closed) which can be used by you to sound your buzzer or whatever you need.<\/li>\n<li>Mains switch<\/li>\n<li>Humidity switch<\/li>\n<li>Alarm lights<\/li>\n<li>Safety fuses<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Mod. 1700CFU<\/h3>\n<ul>\n<li>Int.\u00a0 dimensions mm. 1600 x\u00a0\u00a0 780 x 1430 (wxdxh)<\/li>\n<li>Ext. dimensions mm. 1720 x 1060 x 2120 (wxdxh)<\/li>\n<li>1784 capacity<\/li>\n<li>N<span class=\"upd\">\u00b0<\/span> 4 casters (n.2 free n.2 with stopblock)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong> 230\/1 &#8211; 50 Hz \u00a0<\/strong>Electric system according to CEI 62-25\u00a0 &#8211; CE Marking<\/p>\n<p><strong>Optional:<\/strong><\/p>\n<ul>\n<li>FDA approved Digital Video Recorder<\/li>\n<li>IQ\/OQ Protocols<\/li>\n<li>Temperature\/Humidity Protocols<\/li>\n<\/ul>\n<p><a href=\"http:\/\/lucanegri.biz\/cavallosrl\/wp-content\/uploads\/2014\/12\/900CFU-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-133\" src=\"http:\/\/lucanegri.biz\/cavallosrl\/wp-content\/uploads\/2014\/12\/900CFU-2.png\" alt=\"900CFU-2\" width=\"168\" height=\"130\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"woo-sc-ilink\"><a class=\"info\" href=\"\">Download PDF<\/a><\/span>&#8220;]Download PDF[\/ilink]<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>STABILITY TEST CHAMBER mod. 1700CFU Temperature range: +15\u00b0C\/+50\u00b0C (accuracy \u00b11\u00b0C all over inside the chamber) (read on display \u00b1 0,1) <a class=\"read-more\" href=\"https:\/\/www.cavallocom.it\/en\/stability-test-chamber-1700cfu\/\">&#8230; [read more]<\/a><\/p>\n","protected":false},"author":1,"featured_media":138,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[34],"tags":[],"class_list":["post-141","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-stability-test-chamber"],"_links":{"self":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/141","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/comments?post=141"}],"version-history":[{"count":4,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/141\/revisions"}],"predecessor-version":[{"id":684,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/posts\/141\/revisions\/684"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/media\/138"}],"wp:attachment":[{"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/media?parent=141"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/categories?post=141"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cavallocom.it\/en\/wp-json\/wp\/v2\/tags?post=141"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}